QUALITY CONFORMACE INSPECTIONS (QCI)

Quality Conformance Inspections (QCI) are standard for all MIL-PRF-55310 products.  Sample units are tested in accordance with Group A and Group B requirements for inspection lots.

For space level products, Fre-Tech offers Screening and Quality Conformance testing in accordance with - or superior to - MIL-PRF-55310 and MIL-PRF-38534. Our application note describing the differences in these requirements can be found here.

 

Group A

ELECTRICAL TEST

Supply Voltage, Input Current, Output Waveform, Output Voltage Power, Rise and Fall Times, Duty Cycle, and Start-Up Time (as required)

FREQUENCY-TEMPERATURE STABILITY

Initial Accuracy at Reference Temperature, Initial Frequency-Temperature Accuracy and Frequency-Temperature Tolerance

FREQUENCY-VOLTAGE TOLERANCE

Output Frequency is measured when oscillator supply voltage is adjusted to its specified nominal value up to its maximum / minimum values

OVERVOLTAGE SURVIVABILITY

Overvoltage of 20% above the maximum specified

VISUAL AND MECHANICAL

Verify Material, Design, Construction, Workmanship, Physical Dimensions, and Marking per MIL-PRF-55310

SOLDERABILITY TEST

MIL-STD-202, Method 208

Group B

AGING TEST

Oscillator is energized in oven for a continuous period of 30 days at 70ºC ±3ºC. The Output frequency is measured within an interval of 72 hours maximum per MIL-PRF-55310

 