MIL-PRF-55310D Screening

HI-REL  SCREENING
MIL-PRF-55310, "Class B or S" Screening

When required by the customer, oscillators can be subjected to the following screening  tests on a 100% basis.  PDA for burn-in & Non-Destruct Bond Pull are in accordance with the requirements of MIL-PRF-55310 for "class S" products.

Non-Destruct Bond Pull

MIL-STD-883, Method 2023 ( PDA=2% or 1 wire whichever is greater )

Internal Visual

MIL-STD-883, Method 2017, Class B for Elements, Class S for Workmanship

Stabilization Bake

MIL-STD-883, Method 1008, Cond. C, 24 Hours Minimum

Thermal Shock

MIL-STD-883, Method 1011, Cond. A

Temperature Cycling

MIL-STD-883, Method 1010, Cond. B

Constant Acceleration

MIL-STD-883, Method 2001, Cond. A, Y1 only,( 5000 G )

Seal - fine & gross leak

MIL-STD-883, Method 1014

PIND(Particle Impact Noise Detection)

MIL-STD-883, Method 2020, Cond. A

Radiographic Insp.

MIL-STD-883, Method 2012

Electrical Tests

MIL-PRF-55310, Class B

Burn-in

+125 °C, Nominal Supply Voltage & Burn-in Load, 160 Hours Min.

Electrical Tests

MIL-PRF-55310, Class B