Technical & Design Support
HI-REL SCREENING
MIL-PRF-55310, "Class B or S" Screening
When required by the customer, oscillators can be subjected to the following screening tests on a 100% basis. PDA for burn-in & Non-Destruct Bond Pull are in accordance with the requirements of MIL-PRF-55310 for "class S" products.
|
Non-Destruct Bond Pull |
MIL-STD-883, Method 2023 ( PDA=2% or 1 wire whichever is greater ) |
|
Internal Visual |
MIL-STD-883, Method 2017, Class B for Elements, Class S for Workmanship |
|
Stabilization Bake |
MIL-STD-883, Method 1008, Cond. C, 24 Hours Minimum |
|
Thermal Shock |
MIL-STD-883, Method 1011, Cond. A |
|
Temperature Cycling |
MIL-STD-883, Method 1010, Cond. B |
|
Constant Acceleration |
MIL-STD-883, Method 2001, Cond. A, Y1 only,( 5000 G ) |
|
Seal - fine & gross leak |
MIL-STD-883, Method 1014 |
|
PIND(Particle Impact Noise Detection) |
MIL-STD-883, Method 2020, Cond. A |
|
Radiographic Insp. |
MIL-STD-883, Method 2012 |
|
Electrical Tests |
MIL-PRF-55310, Class B |
|
Burn-in |
+125 °C, Nominal Supply Voltage & Burn-in Load, 160 Hours Min. |
|
Electrical Tests |
MIL-PRF-55310, Class B |