MIL-STD-883 Group A
|
Test
|
MIL-STD-883
|
|
Description
|
Method
|
Condition
|
In House
|
|
Salt Spray
|
1001
|
-
|
|
|
Moisture Resistance
|
1002
|
II
|
|
|
Mechanical Shock
|
2004
|
-
|
|
|
Barometric Pressure
|
3001
|
-
|
|
|
Internal Visual
|
2017
|
-
|
|
|
Stabilization Bake
|
1008
|
24 hrs @ 150°C
|
|
|
Temperature Cycle
|
1010
|
-65°C to 150°C
|
|
|
Constant Acceleration
|
2001
|
5000 G y1
|
|
|
Hermetic Seal (Fine & Gross)
|
1014
|
A and C
|
|
|
Burn In
|
1015
|
168 hrs @ 85°C
|
|
|
External Visual
|
2009
|
-
|
|
|
Steady State Life
|
108
|
D
|
|
MIL-STD-202 Group B
|
Test
|
MIL-STD-202
|
|
Description
|
Method
|
Condition
|
|
Vibration
|
204
|
G
|
|
Thermal Shock
|
107
|
A-1
|
|
Salt Spray
|
1009
|
A
|
|
Moisture Resistance
|
106
|
-
|
|
Mechanical Shock
|
213
|
I
|
|
Barometric Pressure
|
105
|
C
|
|
Resistance to Solder Heat
|
210
|
B
|
|
Lead Integrity
|
2004
|
B2
|
MIL-PRF-38534F Group C
|
Test
|
Method
|
Conditions (PI)
|
|
External Visual
|
2009
|
|
|
PIND
|
2020
|
|
|
Temperature Cycling
|
1010
|
C, 20 Cycles
|
|
Temperature Cycling
|
1010
|
C, 10 Cycles
|
|
Mechanical Shock
|
2002
|
B, Y1 Direction or 3000 g's, Y1 Direction
|
|
Seal (Fine and Gross)
|
1014
|
|
|
Visual Examination
|
1010
|
|
|
Endpoint Electrical
|
*
|
|
|
Steady state life
|
1005
|
1000 hours at 125°C or equivalent (1005)
|
|
Endpoint Electrical
|
*
|
|
|
Internal Water Vapor
|
1018
|
|
|
Internal Visual and Mechanical
|
2014
|
|
|
Wire bond strength
|
2011
|
|
|
Element Shear
|
2019
|
|
|
ESD
|
3015
|
|
|
* in accordance with the applicable device specification
|
MIL-PRF-38534F Group D
|
Description
|
Method
|
Condition (PI)
|
|
Thermal Shock
|
1011
|
C
|
|
Stabilization Bake
|
1008
|
150°C, 1 Hour
|
|
Lead Integrity
|
2004
|
B2
|
|
Seal (Fine and Gross)
|
1014
|
A, D
|
|
Salt Atmosphere
|
1009
|
A, D
|
|
Metal Package Isolation
|
1003
|
600 V DC , 100 nA Max.
|
MIL-PRF-38534F Class K
|
Test
|
Method
|
Conditions (PI)
|
|
Preseal Burn-in
|
1030
|
|
|
Non-Destructive Bond Pull
|
2023
|
|
|
Internal Visual
|
2017
|
|
|
Temperature Cycling
|
1010
|
C, 10 Cycles
|
|
Mechanical Shock or
Constant Acceleration
|
2002/2001
|
B, (Y1 Direction) 3000 g's, Y1 Direction only
|
|
PIND
|
2020
|
Condition A shall be used for Class K,
unless otherwise specified.
|
|
Pre Burn-in Electrical
|
*
|
|
|
Burn-in
|
1015
|
|
|
Final Electrical Test
|
*
|
|
|
Seal (Fine and Gross)
|
1014
|
|
|
Radiographic**
|
2012
|
|
|
External Visual
|
2009
|
|
|
* in accordance with the applicable device specification
** Will be designed to meet requirements, but Radiographic Test Results not included.
|
|